The HDG K10-33 is characterised by maximum economy in all areas and the particularly small footprint.
1
2
3
4
5
6
7
8
9

K10 |
K15 |
K21 |
K26 |
K33 |
|
| Nominal thermal power (kW) | 9,9 | 15 | 21 | 25,9 | 32,5 |
| Power range (kW) | 3,0 - 9,9 | 4,3 - 15 | 6,3 - 21 | 7,6 - 25,9 | 9,8 - 32,5 |
| Flue gas mass flow (kg/s) | 0,0058 | 0,0085 | 0,0118 | 0,0146 | 0,0180 |
| Water capacity (l) | 39 | 39 | 47 | 47 | 47 |
| Max. permissible operating pressure (bar) | 3 | 3 | 3 | 3 | 3 |
| Flue draught requirement (Pa) | 5 | 5 | 5 | 5 | 5 |
| Permissible flow temperature (°C) | 60-75 | 60-75 | 60-75 | 60-75 | 60-75 |
| Permissible flow temperature for buffer operation (°C) | 85 | 85 | 85 | 85 | 85 |
K10 |
K15 |
K21 |
K26 |
K33 |
|
| Height incl. reservoir with suction system (mm) | 1705 | 1705 | 1705 | 1705 | 1705 |
| Width with suction system (mm) | 1075 | 1075 | 1075 | 1075 | 1075 |
| Depth without flue gas pipe connection with suction system (mm) | 710 | 710 | 780 | 780 | 780 |
| Flue gas pipe diameter (mm) | 130 | 130 | 130 | 130 | 130 |
| Weight (kg) | 261 | 261 | 283 | 283 | 283 |
K10 |
K15 |
K21 |
K26 |
K33 |
|
| Boiler energy efficiency class | A+ | A+ | A+ | A+ | A+ |
| Boiler + controller energy efficiency class (class VI) | A+ | A+ | A++ | A++ | A++ |
Pellet boilers are an established heating technology used in a wide range of applications. Depending on the building characteristics, heat demand and local conditions, they may represent an alternative to an existing oil heating system.
Depending on the applicable funding programmes and individual eligibility criteria, financial support may be available for the replacement of an oil heating system. The suitability of a pellet boiler should be assessed based on the specific project requirements.

Suitable for a wide range of boiler rooms and designed for pellet operation across different operating conditions, the HDG K10-33 also offers extended ash removal intervals, depending on fuel quality and system use.
The small footprint, flush wall installation on three sides and easy insertion through a standard doorway make the HDG K10-33 particularly suitable for compact boiler rooms.
Replacing an existing oil heating system with a pellet boiler can be one option during heating system modernisation. The HDG K10-33 is designed for both renovation projects and new installations.

The HDG K10-33 is delivered in separate components and can be brought into the building through a standard doorway. Thanks to its low weight (heaviest component: 170 kg) and compact dimensions, the pellet boiler is also suitable for installation in compact boiler rooms.

The HDG K10-33 is supplied largely pre-assembled. Only a small number of components need to be installed on site, without requiring water-carrying connections.

Thanks to its small footprint of only 0.75 square metres and its low height of 1.70 metres, the HDG K10-33 pellet boiler is suitable for installation in a wide range of boiler rooms. The flush wall installation on three sides and the flue gas pipe, which can be oriented upwards or to the rear, also provide a high degree of installation flexibility.

The combustion technology is designed to support compliance with applicable emission requirements. The precise air control system with a speed-controlled flue gas fan supports stable operation across different load conditions, including part-load operation.

The burner pot and heat exchanger are cleaned automatically, and the combustion residues are compacted in the large-volume ash container. Depending on fuel quality and operating conditions, ash removal is required only at relatively long intervals. In addition to the entry-level version with an internal ash tray, a mobile ash container is also available as an option.

The HDG K10-33 is designed for low electrical power consumption during operation. For example, the HDG K10 consumes approximately 28 watts during regular operation under specified operating conditions. The low-noise ignition element also supports quiet operation.

Condensing technology enables heat contained in the flue gases to be recovered and transferred to the heating system. This allows additional thermal energy from the fuel to be utilised.
System performance depends on operating conditions, fuel quality and system configuration.
The flushing function, consisting of two independent circuits, cleans the corrosion-resistant stainless steel heat exchanger and the condensate collector.
The boiler features a compact design and can be installed close to the wall on two sides. Delivery in separate components supports installation in buildings with restricted access.
The HDG K10-26 condensing boiler is available in four output sizes.

K10 calorific value |
K15 calorific value |
K21 calorific value |
K26 calorific value |
|
| Nominal thermal power (kW) | 10,5 | 15,9 | 22,3 | 27,5 |
| Power range (kW) | 3,2-10,5 | 4,8-15,9 | 6,7-22,3 | 8,2-27,5 |
| Flue gas mass flow (kg/s) | 0,0056 | 0,0079 | 0,0109 | 0,0132 |
| Water capacity (l) | 53 | 53 | 61 | 61 |
| Max. permissible operating pressure (bar) | 3 | 3 | 3 | 3 |
| Flue draught requirement (Pa) | -15 (negative pressure) to +5 (positive pressure) | -15 (negative pressure) to +5 (positive pressure) | -15 (negative pressure) to +5 (positive pressure) | -15 (negative pressure) to +5 (positive pressure) |
| Permissible operating temperature (°C) | 75 | 75 | 75 | 75 |
K10 calorific value |
K15 calorific value |
K21 calorific value |
K26 calorific value |
|
| Height incl. reservoir with suction system (mm) | 1705 | 1705 | 1705 | 1705 |
| Width with suction system (mm) | 1075 | 1075 | 1075 | 1075 |
| Depth without flue gas pipe connection with suction system (mm) | 1015 | 1015 | 1085 | 1085 |
| Flue gas pipe diameter (mm) | 100 | 100 | 100 | 100 |
| Weight (kg) | 277 | 277 | 298 | 298 |
K10 calorific value |
K15 calorific value |
K21 calorific value |
K26 calorific value |
|
| Boiler energy efficiency class | A++ | A++ | A++ | A++ |
| Boiler + controller energy efficiency class (class VI) | A++ | A++ | A++ | A++ |
Find out how easy it is to heat with the HDG and experience our economical pellet boiler as used by our customers.